← incident filesTKT-60007 · RV Quillon · T-1021 · opened 14 Oct 2026, 03:40 UTC

Beam outage

HUBEscalate to the hubS1Beam-wide90% confidence
Customer report
RV Quillon

“Vessel offline since about 02:35 UTC. The crew rebooted the modem twice and nothing changed, so it must be faulty.”

Diagnosis

All 10 terminals on beam B3 (SAT-C 97W) lost rx lock at about 02:35Z and are still offline, on both firmware 4.1.3 and 4.2.1. Antenna beacon signal is normal (about 70%) and pointing error is low. This is a hub, beam or satellite carrier problem, not a fault in the RV Quillon modem.

T-1021T-1022T-1023T-1024T-1025T-1026T-1027T-1028T-1029T-1030
Evidence
  1. Fleet query: all 10 B3 terminals offline, RX_LOCK_LOST, esno_now 0.0, fwd 0.0 Mbps, across two firmware versions
  2. T-1024 modem.log: '2026-10-14T02:35:37Z ERR modem: rx lock lost' at the same minute as T-1021 (T-1021 syslog is +01:00, so 03:35 local is 02:35Z)
  3. T-1021 messages: after the loss, acu 'acquisition complete, locked on beacon peak_sig=74%' and state=TRACKING point_err=0.07-0.12deg sig=70-72%, with 'modem: outroute acquisition retry' repeating
  4. T-1021 show modem: Rx Lock NO, Tx OFF, inhibit 0x02, NOT LOGGED ON (consequence of no outroute lock)
  5. T-1021 messages: buc_current 1.83A, buc_temp 41C, GPS 3D fix with 8 sats before the event, all normal
Evidence gaps
  1. show rf, show acu, show gps, show qos and test dns are not supported on T-1021, so ACU, GPS and RF were checked only through syslog lines and the beacon signal.
  2. No hub-side or beam status was available to confirm the cause of the carrier loss.
Next steps
  1. Escalate to the hub/network team now for a B3 / SAT-C 97W outroute carrier outage that started at about 02:35Z.
  2. Tell the customer that the modem is not faulty and a technician is not needed. Ask the crew to stop rebooting it.
  3. T-1021 logged a 2.3 s ODU supply interruption at 02:35:28Z and the ACU restarted. The ACU re-locked on the beacon and tracking is normal, so no action is needed unless service stays down after the beam is restored.
  4. After the hub restores the carrier, check that the B3 terminals regain lock and logon. If T-1021 does not, re-check it individually.